Circulation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating Pump

Our DL-1000 -25 Degree Cooling Circulating Pump is perfect for lab use and industrial cooling applications. Buy direct from the factory for great value." Please note that the character count includes spaces.
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Parameters
  • Product Features
Overview

Basic Info.

Material
Steel
Type
Cooling Circulator
Temperature Range
-25c~Rt
Compressor
Copeland or Dorin Branded
Transport Package
Export Plywood Box
Specification
700*540*880mm
Trademark
XINCHEN
Origin
China
HS Code
8419899090
Production Capacity
1500sets/Month

Product Description

Circulation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating Pump Circulation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating Pump Circulation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating Pump
Refrigerated Circulators cooling temperature from -120ºC to 30 ºC, widely used for various reactors, distillation or extraction system, laboratory, university research institute, automative, semiconductor and electrical test, chemical, pharmaceutical, petrochemical, biochemical and so on.

We have different models for your choice, with big cooling capacity, high cooling speed, which can greatly improve work efficiency and meet the actual needs of different users.
Product Parameters
Model
DL-0250
DL-0400
DL-0700
DL-1000
DL-1450
DL-2000
DL-2600
Temp.Range
-25ºC~30ºC
Temp control and display
ASET multi-function controller, optional color touch screen operation and display
Temperature control selection
Control the temperature of cooling medium outlet
Communication protocol
MODBUS RTU protocol RS485 interface
Temperature feedback
The built-in cooling medium PT100 feedback
 
Cooling 
capacity
0ºC
1.5KW
2.4KW
4KW
7.5KW
10KW
15KW
20KW
-10ºC
1KW
1.5KW
2.7KW
6.3KW
8KW
12KW
15KW
-20ºC
0.55KW
0.8KW
1.5KW
3.5KW
5KW
7.3KW
10KW
Circulating pump flow rate / Pressure
Max 20L/min; 1.5bar
Max 20L/min; 1.5bar
Max 35L/min; 2.5bar
Max 35L/min; 2.5bar
Max 75L/min; 2.5bar
Max 75L/min; 2.5bar
Max 110L/min; 2.5bar
Storage tank volume
15L
15L
25L
25L
40L
60L
80L
Compressor
Copeland or Dorin
Evaporator
Kaori Plate heat exchanger
Operation panel
Touch button, LCD screen display
Safety protection
Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermel protection device, and other safety protection functions.
Refrigerant
R404A
Interface connector
DN15
DN20
DN20
DN20
DN20
DN20
DN25
Power supply
Single phase AC220V/50Hz
3 Phase AC380V/50HZ
Total power(Max)
1.5KW
2KW
2.5KW
3.5KW
5KW
6.5KW
8.5KW
Dimension
400*600* 1150mm
400*600* 1150mm
500*680* 1350mm
500*680*1350mm
680*700*1650mm
750*750*1800mm
850*850*1850mm
Shell material
Cold rolled plate spray (optional SUS304 shell)
 
Product Features

1. Circulating cooling medium: HTF, industrial alcohol or water-glycol mixture for circulating , conservation of resources.
2. Tight loop piping design, prevent cooling medium pollution, extending the cycle time of the use of cooling medium.
3. Multiple safety protection, more reliable.
4. Imported compressor, cold cascade refrigeration technology.
5. Using cold technology to ensure the stability of low temperatures.
6. It can be set to turn on the compressor and turn off the compressor temperature difference.
7. Ambient temperature detection function to prevent the system operating environment temperature is too high.
8. A variety of fault alarm( over-temperature alarm, sensor alarm, high pressure alarm, compressor overheating alarm, level alarm)
9. A fully enclosed design, low temperature process without water absorbtion, to ensure the purity of the cooling medium, to prevent ice crystals, prelong cooling medium life.
10. High-performance circulating pump, can ensure continuous operation 24 hours a day.
11. Using cold plate heat exchanger to provide heat transfer efficiency.

 

Circulation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating PumpCirculation Cooling Industrial Chiller Lab Use Dl-1000 -25 Degree Cooling Circulating Pump

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours